Lab UPS With Universal Compatibility For LCMS, GCMS, PCR, HPLC, UPLC, ICP-MS, & ICP-OES Available On Amazon

Battery Backup Power, Inc. now offers (2) models of laboratory power protection UPS systems directly on Amazon. Both models have universal compatibility with all make and models LCMS (6kVA & 10kVA), GCMS (6kVA & 10kVA), GC (6kVA & 10kVA), PCR (6kVA & 10kVA), ICP-MS (10kVA), & ICP-OES (10kVA)

These systems keep sensitive instruments running during voltage fluctuations and short duration power outages. Besides providing "always on" backup power, they correct voltage issues at the lab/facility/receptacle so the attached instrument only receives the proper voltage required at all times. For example, if your lab only has 208 volt power and the instrument requires 230 volts, the built in isolation transformer isolates the input voltage and only outputs 230 volts to the instrument. There are both 115 volt and 230 volt receptacles so each instrument plus its peripherals can all plug into the same UPS. An example would be a computer & LC plugged into the 115 volt receptacles and the MS component plugged into one of the 230 volt receptacles. In (5) separate case studies with instrument manufacturer field service representatives at (5) different labs, the 6kVA and 10kVA have been proven to stop reoccurring board failures.  

Both models look identical other than the 6kVA using a NEMA L6-30P (plug, 200-240 volts, 30 amps) for input and the 10kVA using a NEMA 6-50P (plug, 200-240 volts, 50 amps) for input. The output PDU (power distribution unit) is exactly the same for both models. The 6kVA can support up to 6,000 watts of attached equipment whereas the 10kVA can support up to 10,000 watts of attached load.

Amazon Link For 6kVA: Plug and Play 6 kVA / 6,000 Watt Power Conditioner, Voltage Regulator, & Battery Backup UPS with Built in Isolation Transformer (115/230 Volt Output)

Amazon Link For 10kVA: Plug and Play 10 kVA / 10,000 Watt Power Conditioner, Voltage Regulator, & Battery Backup UPS with Built in Isolation Transformer (115/230 Volt Output)

Battery Backup Power Online Store Link For 6kVA (With Reviews): Plug And Play 6 kVA / 6,000 Watt Power Conditioner, Voltage Regulator, & Battery Backup UPS With Built In Isolation Transformer

Battery Backup Power Online Store Link For 10kVA (With Reviews): Plug And Play 10 kVA / 10,000 Watt Power Conditioner, Voltage Regulator, & Battery Backup UPS With Built In Isolation Transformer

 6kVA & 10kVA Output PDU (Power Distribution Unit) 6kVA & 10kVA UPS
Inside BBP UPS Diagram For Lab UPS

 

6kVA Known Combability List (Not Exhaustive): Ultivo QQQ LC/MS, 6495C QQQ LC/MS, 6470B QQQ LC/MS, 6545 LC/Q-TOF, 6545XT AdvanceBio LC/Q-TOF, 6546 LC/Q-TOF, 6560 Ion Mobility LC/Q-TOF, 6530 Q-TOF LC/MS, 6550 iFunnel Q-TOF LC/MS, RapidFire 400, StreamSelect LC/MS, LC/MSD, LC/MSD iQ, LC/MSD XT, 6230B Time of Flight (TOF) LC/MS, LCMS-9030 Q-TOF LC/MS, LCMS-8060NX LC-MS/MS, LCMS-8060 LC-MS/MS, LCMS-8050 LC-MS/MS, LCMS-8045 LC-MS/MS, LCMS-8040 LC-MS/MS, Nexera Mikros, LCMS-2020 Single Quadrupole Liquid Chromatograph MS (LC/MS), Single Quad Preparative LCMS, Nexera QX Multiplex Analysis, SCEX TripleTOF 6600+, TripleTOF 6600, TripleTOF 5600+, TripleTOF 4600, QTRAP 6500+, QQQ 5500+ LC-MS/MS, QTRAP 4500, QQQ 7500 LC-MS/MS, QQQ 6500+, QQQ 5500+ LC-MS/MS, QQQ 4500, QQQ 3500, TOF/TOF 5800, Avio 220 Max ICP-OES, Avio 550 Max ICP-OES, Avio 560 Max ICP-OES, Orbitrap Eclipse Tribrid MS, Orbitrap ID-X Tribrid MS, Orbitrap Fusion Lumos Tribrid MS, Orbitrap Exploris 480 MS, Orbitrap Exploris 240 MS, Orbitrap Exploris 120 MS, Q Exactive UHMR Hybrid Quadrupole-Orbitrap MS, TSQ Altis, TSQ Quantis, TSQ Fortis, ISQ EM Single Quadrupole MS, ISQ EC Single Quadrupole MS, 5977B GC/MSD, 7000D QQQ GC/MS, 7010B QQQ GC/MS, 7250 GC/Q-TOF, 8890 GC, 8860 GC, 7890B GC, 7820A GC, Intuvo 9000 GC, GCMS-TQ8050 NX QQQ GC-MS/MS, GCMS-TQ8040 NX QQQ GC-MS/MS, GCMS-QP2020 NX Single Quadrupole GC-MS, GCMS-QP2010 SE Single Quadrupole GC-MS, Clarus 590 GC, Clarus 690 GC, ISQ 7000 single quadrupole GC-MS, TSQ 9000 QQQ GC-MS/MS, Orbitrap Exploris GC 240 MS, Orbitrap Exploris GC MS, DFS Magnetic Sector GC-HRMS

6kVA BBP UPS With PCR

6kVA With PCR

BBP 6kVA UPS With SCIEX

6kVA With LCMS

 

10kVA Known Compatibility List (Not Exhaustive): 5800 ICP-OES, 5900 ICP-OES, 5110 ICP-OES, 7850 ICP-MS, 7900 ICP-MS, 8900 Triple Quadrupole ICP-MS, 7800 ICP-MS, ICPE-9800, X500B QTOF, X500R QTOF, NexION 5000 Multi-Quadrupole ICP MS, NexION 2000B ICP MS, NexION 1000 ICP MS, Ultivo QQQ LC/MS, 6495C QQQ LC/MS, 6470B QQQ LC/MS, 6545 LC/Q-TOF, 6545XT AdvanceBio LC/Q-TOF, 6546 LC/Q-TOF, 6560 Ion Mobility LC/Q-TOF, 6530 Q-TOF LC/MS, 6550 iFunnel Q-TOF LC/MS, RapidFire 400, StreamSelect LC/MS, LC/MSD, LC/MSD iQ, LC/MSD XT, 6230B Time of Flight (TOF) LC/MS, LCMS-9030 Q-TOF LC/MS, LCMS-8060NX LC-MS/MS, LCMS-8060 LC-MS/MS, LCMS-8050 LC-MS/MS, LCMS-8045 LC-MS/MS, LCMS-8040 LC-MS/MS, Nexera Mikros, LCMS-2020 Single Quadrupole Liquid Chromatograph MS (LC/MS), Single Quad Preparative LCMS, Nexera QX Multiplex Analysis, SCEX TripleTOF 6600+, TripleTOF 6600, TripleTOF 5600+, TripleTOF 4600, QTRAP 6500+, QQQ 5500+ LC-MS/MS, QTRAP 4500, QQQ 7500 LC-MS/MS, QQQ 6500+, QQQ 5500+ LC-MS/MS, QQQ 4500, QQQ 3500, TOF/TOF 5800, Avio 220 Max ICP-OES, Avio 550 Max ICP-OES, Avio 560 Max ICP-OES, Orbitrap Eclipse Tribrid MS, Orbitrap ID-X Tribrid MS, Orbitrap Fusion Lumos Tribrid MS, Orbitrap Exploris 480 MS, Orbitrap Exploris 240 MS, Orbitrap Exploris 120 MS, Q Exactive UHMR Hybrid Quadrupole-Orbitrap MS, TSQ Altis, TSQ Quantis, TSQ Fortis, ISQ EM Single Quadrupole MS, ISQ EC Single Quadrupole MS, 5977B GC/MSD, 7000D QQQ GC/MS, 7010B QQQ GC/MS, 7250 GC/Q-TOF, 8890 GC, 8860 GC, 7890B GC, 7820A GC, Intuvo 9000 GC, GCMS-TQ8050 NX QQQ GC-MS/MS, GCMS-TQ8040 NX QQQ GC-MS/MS, GCMS-QP2020 NX Single Quadrupole GC-MS, GCMS-QP2010 SE Single Quadrupole GC-MS, Clarus 590 GC, Clarus 690 GC, ISQ 7000 single quadrupole GC-MS, TSQ 9000 QQQ GC-MS/MS, Orbitrap Exploris GC 240 MS, Orbitrap Exploris GC MS, DFS Magnetic Sector GC-HRMS

BBP 10kVA UPS With ICP-MS

10kVA With ICP-MS

BBP 10kVA UPS With Thermo Fisher

10kVA With LCMS

Leave a comment

Please note, comments must be approved before they are published