10 kVA / 10,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner
10 kVA / 10,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner
10 kVA / 10,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner With 1 External Battery Pack
10 kVA / 10,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner With 2 External Battery Packs
10 kVA / 10,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner With 3 External Battery Packs
10 kVA / 10,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner With 4 External Battery Packs
10 kVA / 10,000 Watt N+1 Digital Tower Battery Backup UPS And Power Conditioner With 5 External Battery Packs
10 kVA / 10,000 Watt Power Conditioner, Voltage Regulator, & Battery Backup UPS With Built In Isolation Transformer
Digital Signal Processing
6KVA 10KVA BBP UPS On Unistrut In Facility Providing Backup Power To Electrical Sub Panel - Back
6KVA 10KVA BBP UPS On Unistrut In Facility Providing Backup Power To Electrical Sub Panel - Front
6KVA 10KVA BBP UPS On Unistrut In Facility Providing Backup Power To Electrical Sub Panel - Side
6KVA 10KVA BBP UPS With Extended Backup Time 2 Hour External Battery Packs In Facility Providing Backup Power To Electrical Sub Panel For Extraction Booth
6KVA 10KVA BBP UPS With Extended Backup Time Multiple Day External Battery Packs In Facility Providing Backup Power To Electrical Sub Panel For Critical Life Safety Fire Alarm Equipment UL924
6KVA 10KVA BBP UPS Providing Critical Emergency Backup Power To Facility Plus Voltage Regulation, Frequency Correction, And Power Conditioning To Electrical Sub Panel - Back
6KVA 10KVA BBP UPS Providing Critical Emergency Backup Power To Facility Plus Voltage Regulation, Frequency Correction, And Power Conditioning To Electrical Sub Panel - Front
6KVA 10KVA BBP UPS Providing Critical Emergency Backup Power To Facility Plus Voltage Regulation, Frequency Correction, And Power Conditioning To Electrical Sub Panel - Front Close Up View
6KVA 10KVA BBP UPS Providing Critical Emergency Backup Power To Facility Plus Voltage Regulation, Frequency Correction, And Power Conditioning To Electrical Sub Panel - Front LCD View Of Current Facility Voltage
(2) 6KVA 10KVA BBP UPS Running Wired In Parallel N+1 With Connection Sync Box Providing Critical Emergency Backup Power To Facility Plus Voltage Regulation, Frequency Correction, And Power Conditioning To Electrical Sub Panel - Dual UPS View
(2) 6KVA 10KVA BBP UPS Running Wired In Parallel N+1 With Connection Sync Box Providing Critical Emergency Backup Power To Facility Plus Voltage Regulation, Frequency Correction, And Power Conditioning To Electrical Sub Panel - Box View
6KVA And 10KVA Hardwire Diagram With Bonding Jumper

10 kVA / 10,000 Watt Power Conditioner, Voltage Regulator, & Battery Backup UPS With Built In Isolation Transformer

Regular price
$ 6,999.99
Sale price
$ 6,999.99
Regular price
Sold out
Unit price
per 

Complete 5 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Heavy Duty Isolation Transformer, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology.

Extreme Energy Savings - Saves up to $3,153.60 per year over older model 10 KVA UPS systems in annual electricity costs due to energy efficiency enhancements.

Multiple Backup Time Options:

Model Number: Description (Under Battery Options Drop Down): Approximate Backup Time At Full Load:
BBP-ADV-10000-PSW-ONL UPS With Internal Batteries Only (20 Batteries, 12 Volts, 9 Amp Hours Each) 2.16 KWH 11 Minutes
BBP-ADV-10000-PSW-ONL-WEBPWC UPS Plus 1 Extra External Battery Pack (80 Batteries, 12 Volts, 9 Amp Hours Each) 8.64 KWH 46 Minutes
BBP-ADV-10000-PSW-ONL-W2EBPWC UPS Plus 2 Extra External Battery Packs (140 Batteries, 12 Volts, 9 Amp Hours Each) 15.12 KWH 1 Hour 21 Minutes
BBP-ADV-10000-PSW-ONL-W3EBPWC UPS Plus 3 Extra External Battery Packs (200 Batteries, 12 Volts, 9 Amp Hours Each) 21.60 KWH 1 Hour 56 Minutes
BBP-ADV-10000-PSW-ONL-W4EBPWC UPS Plus 4 Extra External Battery Packs (260 Batteries, 12 Volts, 9 Amp Hours Each) 28.08 KWH 2 Hours 31 Minutes
BBP-ADV-10000-PSW-ONL-W5EBPWC UPS Plus 5 Extra External Battery Packs (320 Batteries, 12 Volts, 9 Amp Hours Each) 34.56 KWH 3 Hours 6 Minutes
  
  • 10000 VA (10 kVA) / 10,000 Watt (10 kW)
  • N+1 And Parallel Operation Up To 40 kVA (4 Units In Series)
  • Energy Efficient/High Efficiency UPS Mode
  • LCD Status Measurements Include Voltage, Frequency, Load Level, Battery Level, Output Current, and Estimated Remaining Backup Time
  • Tower With Casters
  • Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
  • Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay (Phase Locked To Input Power Source)
  • Wide Frequency Input Range (44-66 Hz Auto Sensing) Allows For Generator Power To Be Used As A Primary Or Secondary Input Power Source (Using Automatic Transfer Switch Before UPS)
  • Constant Voltage Regulation (±1%)
  • Constant Frequency Regulation (±1 or ±3% Selectable)
  • Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries
  • Optional Extended Warranty: 5 Years On Electronics And 1 Year Warranty On Batteries
  • Digital Signal Processing (DSP) Allows For Greater Reliability Over Older UPS Designs And Superior Electric Noise Filtration
  • >0.99 Input Power Factor / 0.9 Output Power Factor (Line Mode) / High Efficiency Mode For Superior Efficiency And Power Savings
  • INPUT OPTIONS: Hardwire Terminal Block, NEMA 5-15P (Plug), NEMA 5-20P (Plug), NEMA L5-30P (Plug), NEMA 6-15P (Plug), NEMA 6-20P (Plug), NEMA L6-15P (Plug), NEMA L6-20P (Plug), NEMA L6-30P (Plug), NEMA L14-30P (Plug), NEMA 6-50P (Plug), NEMA 14-50P (Plug), Hubbell CS8265C (Plug), Or Custom (Contact Us For Custom Or Unlisted Options)
    • 110-280 VAC Single Phase Maximum Range
    • 200-240 VAC Single Phase Recommended Range, 50 Amps 
  • OUTPUT OPTIONS: Hardwire Terminal Block, NEMA 5-15R (Receptacle), NEMA 5-20R (Receptacle), NEMA L5-30R (Receptacle), NEMA 6-15R (Receptacle), NEMA 6-20R (Receptacle), NEMA L6-15R (Receptacle), NEMA L6-20R (Receptacle), NEMA L6-30R (Receptacle), NEMA L14-30R (Receptacle), NEMA 6-50R (Receptacle), NEMA 14-50R (Receptacle), Or Custom (Contact Us For Custom Or Unlisted Options)
    • 120, 110/220, 115/230, 120/240, 120/208, 208, 220, 230, or 240 Volts Single Phase
    • UPS Weight (Excluding Optional External Battery Packs): 294 lbs.
    • Dimensions (Inches): 11.4 X 26 X 28 (W x H x D)
    • Operating Temperature: 32°-104° F
    • Operating Humidity: 20%~95%, Non-Condensing
    • Operating Elevation: 3,280 Feet Without De-Rating 
    • Cold Start Capable (Shipped With Cold Start Disabled, Will Enable Automatically After Receiving Power For The First Time After Shipping)
    • cTUVus, cULus, and FCC Certified
    • Includes Software For Windows Monitoring & Configuration 

    Replacement Batteries:
    -Leoch DJW12-9.0 (Lead Acid), Leoch LP12-9.0 (Lead Acid)Betta Batteries 6-HCNFJ-7.2 (Lead Crystal), Or Battery Backup Power BBP-LIFEPO4-HDR-12V-7.2AH (Lithium Iron Phosphate)

    Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com. 

    Customer Reviews

    Based on 4 reviews
    100%
    (4)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    0%
    (0)
    M
    Meghjit Power Solutions LLP

    I am really impressed with your blog, such great & useful knowledge you mentioned here. Your post is very informative. Thanks for sharing and keep it up like this. You can know more please visit at Line Interactive UPS.

    T
    Tim Woods
    Easy to wire

    This unit is fantastic and versatile. It has a built in isolation transformer which allows you to select/wire pretty much any output voltage configuration you want. The input is 2 hots (L12 and N1) and 1 ground (G1). The N1 name is misleading, it is really for the second hot. If you were in another country where 230 VAC is the default, I guess it would neutral, but in the US, its HOT 2. The output terminal allows for a variety of configurations, but I always use 120/240VAC split phase. To get that, you put the included jumper on N11 and L22. Then output HOT 1 is N22, output NEUTRAL is either N11 or L22 (jumper), output HOT 2 is L11, and output GROUND is G2.

    M
    Marilyn
    Stopped Power Blips, Glitches, And Voltage Drops

    Our lab purchased (12) of the hardwire version of this UPS, one per instrument desk. Ever since our electrician installed these, we no longer experience instrument restarts, voltage issues, or any other power related issue. Thank goodness since every time the air compressor started (prior to installing these), everything in our lab lost power. Runs that take 4-8 hours would constantly need to be restarted. These 10KVA UPS systems have saved us so much money in labor and time.

    G
    Guest Guest
    Excellent product for seamless backup power and cleaning up voltage issues

    We have 208VAC (really 204VAC) in our lab and our instruments require 230VAC. This unit provides backup to our instruments and corrects the facility voltage to a steady 230VAC which is required to stay within warranty of our instruments.