The battery backup UPS (uninterruptible power supply) and power conditioner for the Illumina HiSeq 3000 DNA sequencer provides automatic seamless emergency backup power to the instrument. Plug the battery backup UPS into an available wall socket, then plug the Illumina HiSeq 3000 into one of the available receptacles on the back of the battery backup UPS, turn it on, and forget about it.
If utility power is lost while the Illumina HiSeq 3000 is on and connected to the battery backup UPS, the instrument will continue to operate as if power was never lost until either power is restored or battery power is depleted (whichever occurs first). The built in power conditioning function ensures that voltage sags or surges will not damage the power supply of the attached instrument.
4 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology (Phase Locked To Utility Power Allowing Seamless Transition To Backup Power).
Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com.
Multiple Backup Time Options:
Model Number: | Description (Under Battery Options Drop Down): | Approximate Backup Time With Illumina HiSeq 3000: |
BBP-AR-2000-PSW-ONL | UPS With Internal Batteries Only | 8 Minutes |
BBP-AR-2000-PSW-ONL-WEBP | UPS Plus 1 Extra External Battery Pack | 25 Minutes |
BBP-AR-2000-PSW-ONL-W2EBP | UPS Plus 2 Extra External Battery Packs | 42 Minutes |
- 2000 VA (2 kVA) / 1,800 Watt (1.8 kW)
- 55-150 Volt AC Input / 100/110/115/120/127 Volt AC Output
- Energy Efficient/High Efficiency UPS Mode >96.5% Efficiency When Enabled
- LCD Status Measurements Include Voltage, Frequency, Load Level, Battery Level, Output Current, and Estimated Remaining Backup Time
- Tower
- Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
- Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay (Phase Locked To Input Power Source)
- Wide Frequency Input Range (44-66 Hz Auto Sensing) Allows For Generator Power To Be Used As A Primary Or Secondary Input Power Source (Using Automatic Transfer Switch Before UPS)
- Constant Voltage Regulation (±1%)
- Constant Frequency Regulation (±1 or ±3% Selectable)
- Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries
- Optional Extended Warranty: 5 Years On Electronics And 1 Year Warranty On Batteries
- Digital Signal Processing (DSP) Allows For Greater Reliability Over Older UPS Designs And Superior Electric Noise Filtration
- >0.99 Input Power Factor / 0.92 Output Power Factor (Line Mode) / 0.965 Output Power Factor (High Efficiency Mode) For Superior Efficiency And Power Savings
- INPUT: 120 Volt, 20 Amp NEMA 5-20P (Plug)
- OUTPUT: 8x 120 Volt, NEMA 5-15/20R Battery & Surge Protected Receptacles (Standard Wall Receptacles)
- Weight: 47.4 lbs.
- Dimensions (Inches): 6.73 X 11.3 X 17.4 (W x H x D)
- Operating Temperature: 32°-104° F
- Operating Humidity: 20%~95%, Non-Condensing
- Operating Elevation: 3,280 Feet Without De-Rating
- Cold Start Capable (Shipped With Cold Start Disabled, Will Enable Automatically After Receiving Power For The First Time After Shipping)
- cTUVus, cULus, and FCC Certified
- Includes Software For Windows Monitoring & Configuration
- Free Shipping/Freight Within The United States Or To U.S. Based Freight Forwarder Specified Location (List U.S. Based Location Specified By Forwarder In Shipping Address For International Orders)
User Guides:
-Battery Backup Power Tower UPS User Guide.pdf
-Battery Backup Power Tower External Battery Pack User Guide.pdf
Spec Sheet/Cut Sheet:
-BBP Tower DSP Series Specification Sheet.pdf
Replacement Batteries:
-Leoch DJW12-9.0 (Lead Acid), Yuasa 7.5-12 (Lead Acid), Yuasa REW45-12 (Lead Acid), Or Battery Backup Power BBP-LIFEPO4-HDR-12V-7.2AH (Lithium Iron Phosphate)