Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq
Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq Back View
Power Synchronization Technology Double Conversion Battery Backup UPS No Transfer Delay To Backup Power
Pure True Clean Sine Wave Output Battery Backup UPS
DSP (Digital Signal Processing) Battery Backup UPS
Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq
Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq
  • Load image into Gallery viewer, Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq
  • Load image into Gallery viewer, Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq Back View
  • Load image into Gallery viewer, Power Synchronization Technology Double Conversion Battery Backup UPS No Transfer Delay To Backup Power
  • Load image into Gallery viewer, Pure True Clean Sine Wave Output Battery Backup UPS
  • Load image into Gallery viewer, DSP (Digital Signal Processing) Battery Backup UPS
  • Load image into Gallery viewer, Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq
  • Load image into Gallery viewer, Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq

Battery Backup UPS (Uninterruptible Power Supply) And Power Conditioner For Illumina NovaSeq

Regular price
$ 1,699.99
Sale price
$ 1,699.99
Regular price
Sold out
Unit price
per 

The battery backup UPS (uninterruptible power supply) and power conditioner for the Illumina NovaSeq DNA sequencer provides automatic seamless emergency backup power to the instrument. Plug the battery backup UPS into an available wall socket, then plug the Illumina NovaSeq into one of the available receptacles on the back of the battery backup UPS, turn it on, and forget about it.

If utility power is lost while the Illumina NovaSeq is on and connected to the battery backup UPS, the instrument will continue to operate as if power was never lost until either power is restored or battery power is depleted (whichever occurs first). The built in power conditioning function ensures that voltage sags or surges will not damage the power supply of the attached instrument. 

4 Tier Power Protection System – Surge Protection, Real Time Power Conditioning With Voltage Regulation, Pure Sine Wave Output, & Always On Double Conversion Backup Power Technology (Phase Locked To Utility Power Allowing Seamless Transition To Backup Power).
Do you need a PDF quote or a custom emergency backup solution? Email us at engineering@batterybackuppower.com


Multiple Backup Time Options:

Model Number: Description (Under Battery Options Drop Down): Approximate Backup Time With Illumina NovaSeq:
BBP-AR-3000-PSW-ONL-220V UPS With Internal Batteries Only 7 Minutes
BBP-AR-3000-PSW-ONL-220V-WEBP UPS Plus 1 Extra External Battery Pack 22 Minutes
BBP-AR-3000-PSW-ONL-220V-W2EBP UPS Plus 2 Extra External Battery Packs 38 Minutes

 

  • 3000 VA (3 kVA) / 2,700 Watt (2.7 kW)
  • 208/220/230/240 Volt AC Output
  • Energy Efficient/High Efficiency UPS Mode >96.5% Efficiency When Enabled
  • LCD Status Measurements Include Voltage, Frequency, Load Level, Battery Level, Output Current, and Estimated Remaining Backup Time
  • Tower
  • Pure Sine Wave Clean Output To Operate And Maximize The Life Of Even The Most Sensitive Electronics
  • Online (Double Conversion) - Highest Level Of Protection Available - Battery Power Always Engaged, No Switching Delay (Phase Locked To Input Power Source)
  • Wide Frequency Input Range (44-66 Hz Auto Sensing) Allows For Generator Power To Be Used As A Primary Or Secondary Input Power Source (Using Automatic Transfer Switch Before UPS)
  • Constant Voltage Regulation (±1%)
  • Constant Frequency Regulation (±1 or ±3% Selectable)
  • Factory Warranty: 3 Years On Electronics And 1 Year Warranty On Batteries
  • Optional Extended Warranty: 5 Years On Electronics And 1 Year Warranty On Batteries
  • Digital Signal Processing (DSP) Allows For Greater Reliability Over Older UPS Designs And Superior Electric Noise Filtration
  • >0.99 Input Power Factor / 0.92 Output Power Factor (Line Mode) / 0.965 Output Power Factor (High Efficiency Mode) For Superior Efficiency And Power Savings
  • INPUT: 208-240 Volts, 20 Amps, IEC C20
    • INCLUDES L6-20P to C19 Plug Adapter For Wall Receptacle To UPS Connection (Plug And Play)
  • OUTPUT:
    • 1x 208/220/230/240 Volt, IEC C19 Battery & Surge Protected Receptacle
    • 6x 208/220/230/240 Volt, IEC C13 Battery & Surge Protected Receptacles
    • INCLUDES C20 to L6-20R Plug Adapter For Instrument To UPS Connection (Plug And Play)
  • Full Load (2,700 Watts) Estimated Run Time On Battery Power:
    • Up To 11 Minutes On Internal Batteries
      • 6 Batteries, 12 Volts, 9 Amp Hours Each
    • Up To 35 Minutes On Internal Batteries + 1 Battery Pack
      • 18 Batteries, 12 Volts, 9 Amp Hours Each
    • Up To 58 Minutes On Internal Batteries + 2 Battery Packs
      • 30 Batteries, 12 Volts, 9 Amp Hours Each
  • Half Load (1,350 Watts) Estimated Run Time On Battery Power:
    • Up To 23 Minutes On Internal Batteries
      • 6 Batteries, 12 Volts, 9 Amp Hours Each
    • Up To 1 Hours 09 Minutes On Internal Batteries + 1 Battery Pack
      • 18 Batteries, 12 Volts, 9 Amp Hours Each
    • Up To 1 Hours 56 Minutes On Internal Batteries + 2 Battery Packs
      • 30 Batteries, 12 Volts, 9 Amp Hours Each
  • Weight: 67.2 lbs.
  • Dimensions (Inches): 7.6 X 12.6 X 21.8 (W x H x D)
  • Operating Temperature: 32°-104° F
  • Operating Humidity: 20%~95%, Non-Condensing
  • Operating Elevation: 3,280 Feet Without De-Rating 
  • Cold Start Capable (Shipped With Cold Start Disabled, Will Enable Automatically After Receiving Power For The First Time After Shipping)
  • cTUVus, cULus, and FCC Certified
  • Includes Software For Windows Monitoring & Configuration 
  • Free Shipping/Freight Within The United States Or To U.S. Based Freight Forwarder Specified Location (List U.S. Based Location Specified By Forwarder In Shipping Address For International Orders)

User Guides:
-Battery Backup Power Tower UPS User Guide.pdf
-Battery Backup Power Tower External Battery Pack User Guide.pdf

Spec Sheet/Cut Sheet:
-BBP Tower DSP Series Specification Sheet.pdf

Replacement Batteries:
-Leoch DJW12-9.0 (Lead Acid), Yuasa 7.5-12 (Lead Acid), Yuasa REW45-12 (Lead Acid), Or Battery Backup Power BBP-LIFEPO4-HDR-12V-7.2AH (Lithium Iron Phosphate)